- Single Air-conditioning Unit—Water-cooling: It applies to indoor air-conditioning for commercial, residential and industrial building. It is very suitable for place where thermal load in summer is great and no need for heat in winter. It is also the first option for industrial or mining enterprise whose working environment has much thermal load all through year and it is necessary to reduce indoor temperature.
- ◆ AKA-W-EH
- Single Air-conditioning Unit—Electrical-heating: For site where thermal load is great in summer and no need heating in winter.
- ◆ AKA-W-HU
- Single Air-conditioning Unit—Water-cooling Constant Temperature & Humidity: For site where it is required to accurately control the temperature and humidity. Standard operating condition like: Cooling capacity from 15.8 KW to 388KW, heating capacity from 8KW to 120KW and humidification capacity from 4KG/H to 45KG/H.
Water Cooled Scroll Module Unit
Description
AKA- | W- | 15- | GH- | V- | A- | A4 |
Akawell Air Conditioning | Water Cooling | Nominal Cooling Capacity (KW) | GH: Air-cooling
EH: Electric Heater HU: Precision Control |
V: Vertical
H: Horizontal |
Air-out Mode | A4 -R410a |
◆ AKA-W-GH
Single Air-conditioning Unit—Water-cooling: It applies to indoor air-conditioning for commercial, residential and industrial building. It is very suitable for place where thermal load in summer is great and no need for heat in winter. It is also the first option for industrial or mining enterprise whose working environment has much thermal load all through year and it is necessary to reduce indoor temperature.
◆ AKA-W-EH
Single Air-conditioning Unit—Electrical-heating: For site where thermal load is great in summer and no need heating in winter.
◆ AKA-W-HU
Single Air-conditioning Unit—Water-cooling Constant Temperature & Humidity: For site where it is required to accurately control the temperature and humidity. Standard operating condition like: Cooling capacity from 15.8 KW to 388KW, heating capacity from 8KW to 120KW and humidification capacity from 4KG/H to 45KG/H.
Unit Type | Supply Air Way | Model | No. | Diagram | |
Vertical Unit | Side Outflow |
Front Inflow Front Outflow |
AKA-W-15 ~ 80-V | A | / |
Top Outflow |
Front Inflow Top Outflow |
AKA-W-15 ~ 80-V | B | / | |
Back Inflow Top Outflow |
AKA-W-85 ~ 350-V | C | / | ||
Bottom Outflow |
Front Inflow Bottom Outflow |
AKA-W-15 ~ 80-V | D | / | |
Horizontal Unit | Horizontal Outflow |
Front Inflow Back Outflow |
AKA-W-15 ~ 80-V | E | / |
Unit Type | Supply Air Way | Diagram |
Horizontal Unit | According to actual application requirement, Akawell will offer some structural schematic diagrams of functional combination for client’s confirmation. | / |
Unit Type | AKA-W-15-GH- | AKA-W-20-GH- | AKA-W-35-GH- | ||
Air Volume | M3/H | 3,000 | 4,000 | 6,000 | |
Refrigerating Capacity | KW | 15.8 | 18.5 | 33 | |
Heating Capacity (Electrical Heating) |
KW | 8 | 10 | 15 | |
Humidification Capacity (Constant Temperature & Humidity) |
KGS/H | 4 | 4 | 8 | |
Static Pressure | Pa | 100 | 120 | 150 | |
Unit’s Noise | dB(A) | 64 | 65 | 66 | |
Refrigerating Power | KW | 5.05 | 6.04 | 9.61 | |
Max Total Power (Constant Temperature & Humidity) |
KW | 15.85 | 18.8 | 30.21 | |
Power | 380V/3PH/50Hz | ||||
Air-out Way | Side/Top | ||||
Blower Way |
Double-inlet Wind Centrifugal Blower (Direct Connection With Outer Rotor/Belt Gearing) |
||||
Temperature Range | 24℃~30℃±1℃ | ||||
Air Filter |
Primary Filter for Ordinary Cabinet Panel Primary Filter G4 for Constant Temperature & Humidity Unit |
||||
Compressor | Type | Fully Enclosed Scroll Compressor | |||
Max Operating Current | A | 10 | 12 | 20 | |
Refrigerating | Type | R22/R410a | |||
Filling Quantity | KG | 4 | 5 | 8 | |
Cooling Water Side | Water Flow Amount | M3/H | 3 | 4 | 6.8 |
Connecting Pipe Specification | IN | 1″ | 1″ | 1-1/2″ | |
Water Side Resistance | Kpa | 25 | 30 | 30 | |
Overall Dimensions(H-Horizontal Unit) | Length | MM | 1,150 | 1,150 | 1,150 |
Width | MM | 1,800 | 1,800 | 1,950 | |
Height | MM | 800 | 800 | 950 | |
Net Weight | KGS | 230 | 240 | 280 | |
Overall Dimensions(V-Vertical Unit) | Length | MM | 1,150 | 1,150 | 1,400 |
Width | MM | 650 | 650 | 650 | |
Height | MM | 1,850(Side Out-let 2,200) | 1,850(Side Out-let 2,200) | 1,850(Side Out-let 2,200) | |
Net Weight | KGS | 220/240 | 230/250 | 280/300 |
AKA-W-40-GH- | AKA-W-50-GH- | AKA-W-65-GH- | AKA-W-80-GH- | AKA-W-100-GH- |
7,000 | 9,000 | 11,000 | 13,000 | 16,000 |
40 | 48.8 | 66 | 76 | 100 |
16 | 20 | 30 | 40 | 45 |
8 | 15 | 15 | 15 | 15 |
150 | 180 | 200 | 250 | 300 |
67 | 68 | 70 | 71 | 72 |
11.58 | 15.1 | 19.7 | 23.2 | 33.1 |
33.18 | 45.6 | 60.2 | 73.7 | 88.5 |
380V/3PH/50Hz | ||||
Side/Top | Horizontal/Top | |||
Double-inlet Wind Centrifugal Blower (Direct Connection With Outer Rotor/Belt Gearing) |
Double-inlet Wind Centrifugal Blower(Belt Gearing) | |||
24℃~30℃±1℃ | ||||
Primary Filter for Ordinary Cabinet Panel Primary Filter G4 for Constant Temperature & Humidity Unit |
||||
Fully Enclosed Scroll Compressor | ||||
22 | 10 – 22 | 2 x 20 | 2 x 22 | 3 x 20 |
R22/R410a | R410a | |||
9 | 4 + 8 | 2 x 8 | 2 x 9 | 3 x 8 |
8.3 | 10.1 | 13.6 | 15.7 | 19.5 |
1-1/2″ | 2″ | 2-1/2″ | 2-1/2″ | 2-1/2″ |
30 | 33 | 35 | 35 | 38 |
1,150 | 1,440 | 1,440 | 1,440 | / |
1,950 | 2,350 | 2,350 | 2,350 | / |
950 | 1,050 | 1,050 | 1,050 | / |
300 | 400 | 600 | 650 | / |
1,400 | 1,900 | 2,100 | 2,100 | 2,100 |
650 | 650 | 650 | 650 | 1200 |
1,850(Side Out-let 2,200) | 2,000(Side Out-let 2,400) | 2,050(Side Out-let 2,400) | 2,050(Side Out-let 2,400) | 2,050 |
300/320 | 400/450 | 650 | 800 | 1,100 |
Remark |
1. Standard operating condition: inlet and outlet temperature of cooling water–30℃/35℃. 2. According to customer’s need, we can design non-standard models. Welcome business consultation. |
AKA-W-140-GH- | AKA-W-170-GH- | AKA-W-260-GH- | AKA-W-350-GH- |
22,000 | 30,000 | 45,000 | 60,000 |
144 | 172 | 255 | 338 |
65 | 65 | 100 | 120 |
23 | 23 | 32 | 45 |
350 | 350 | 450 | 500 |
74 | 76 | 78 | 80 |
51.3 | 56.6 | 82.5 | 112 |
130.3 | 137.8 | 203.5 | 260 |
380V/3PH/50Hz | |||
Horizontal/Top | |||
Double-inlet Wind Centrifugal Blower(Belt Gearing) | |||
24℃~30℃±1℃ | |||
Primary Filter for Ordinary Cabinet Panel Primary Filter G4 for Constant Temperature & Humidity Unit |
|||
Fully Enclosed Scroll Compressor | |||
4 x 22 | 2 x 45 | 3 x 45 | 4 x 45 |
R22/R410a | |||
4 x 9 | 2 x 20 | 3 x 20 | 4 x 20 |
29.7 | 35.5 | 57.5 | 70.1 |
3″ | 3″ | 3″ | 4″ |
35 | 38 | 40 | 40 |
/ | / | / | / |
/ | / | / | / |
/ | / | / | / |
/ | / | / | / |
2,100 | 2,100 | 3,200 | 3,200 |
1,400 | 1,400 | 1,800 | 1,800 |
2,050 | 2,050 | 2,400 | 2,400 |
1,420 | 1,650 | 2,100 | 2,300 |
Remarks |
1. Standard operating condition: Inlet and outlet temperature of chilling water– 30℃/35℃. 2. According to customer’s need, we can design non-standard models. Welcome business consultation. |