>>>Clean Operating Room Air Conditioning Unit

Clean Operating Room Air Conditioning Unit

  • Anti-cold bridge cabinet, flexible combination of frame, smooth internal structure, easy to clean
  • Double panel structure, 30mm, 50mm thickness available
  • The cabinet can withstand pressure up to 2000pa.
  • Hot and cold water performance is approved by AHRI410
  • The cabinet is verified by VDI
  • The cabinet is certified by EUROVENT
  • Optional direct expansion system

Description

  1. Represent clean operating room air conditioning unit
  2. Structure type: L-vertical unit, W-horizontal unit, D-ceiling unit
  3. Nominal air volume (*1000m3/h)
  4. S=water cooling, straight expansion does not show
  5. Working conditions: H-return air, X-new wind, mixed air does not display
  • Anti-cold bridge cabinet, flexible combination of frame, smooth internal structure, easy to clean
  • Double panel structure, 30mm, 50mm thickness available
  • The cabinet can withstand pressure up to 2000pa.
  • Hot and cold water performance is approved by AHRI410
  • The cabinet is verified by VDI
  • The cabinet is certified by EUROVENT
  • Optional direct expansion system

Medical purification air conditioning unit parameter table description:

Return air condition: Summer DB24℃/WB17.5℃  Winter DB23℃/WB15.5℃

Chilled water inlet and outlet temperature:7℃/12℃

Hot water inlet and outlet temperature: 60℃/50℃

Steam temperature pressure: 130℃/0.2Mpa

Fresh air pretreatment: Summer DB12℃/WB12℃  Winter DB25℃

The parameter with “*” in the table is a non-standard configuration of the device.

Electric reheating is divided into two forms, and the user can select one according to the size of the demand.

When ordering, users can choose cooling, heat, electric reheating, humidification, and filter rating according to different areas.

Medical air conditioning purification air conditioning unit parameters

(cold water circulation type / fresh air independent treatment)

Performance / Model YJ02-S YJ02.5-S YJ03-S YJ03.5-S YJ04-S YJ04.5-S YJ05-S YJ05.5-S YJ06-S YJ06.5-S YJ07-S
Rated volume m3/h 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000
External pressure Pa 650 650 650 650 650 650 650 650 650 650 650
Motor power Kw 1.5 2.2 2.2 2.2 3 3 3 3 4 4 4
Off-machine noise dB(A) ≤68 ≤70 ≤70 ≤70 ≤70 ≤70 ≤70 ≤70 ≤70 ≤72 ≤72
Cooling capacity
Kw
2-row tube 4.42 5.56 6.61 7.6 8.9 10.2 11.1 12.6 13.8 15.02 16.2
3-row tube 7 8.6 10.5 11.5 14.45 16.34 18.15 19.91 21.9 29.92 25.7
4-row tube 8.7 11 13.5 14.6 18.24 20.52 22.85 25.14 27.46 29.9 32.31
Water resistance  Kpa ≤ 55
Heating capacity
KW
2 rows of hot water coil * 9.2 11.5 13.65 15.93 18.24 20.52 22.85 25.1 27.4 30.5 32.9
1 rows of steam coils * 12 15.1 18.2 21.4 24.6 27.3 30.2 33.1 36.5 40.1 42.6
Water resistance  Kpa ≤ 50
Electric heating Form(I)Kw 2 2.5 3 3 4 4 5 5 6 6 7
Form ( II ) Kw 4 5 5 5 6 6 7.5 7.5 9 9 10.5
Humidification Power KW <6.0 <6.0 <6.0 <6.0 <6.0 <6.0 <7.5 <7.5 <7.5 <7.5 <9.8
Humidification amount Kg/h ≤8.0 ≤8.0 ≤8.0 ≤8.0 ≤8.0 ≤8.0 ≤10 ≤10 ≤10 ≤10 ≤13
Coarse effect Type Plate type (multiple pleats) / chemical fiber non-woven filter material
Filter Filtration efficiency G4     particle size ≥ 5μm     Filtration efficiency≥75%
Initial / final resistance
Pa
≤50 / 100
Medium effect filter Type Bag type (Chemical fiber)
Filtration efficiency F8    Particle size≥1μm     Filtration efficiency≥80%
Initial/final resistance
Pa
≤100 / 200
Note: Return air Summer D824℃/WB17.5C Winter DB23°C/WB15.5C Chilled water inlet and outlet temperature 7°C/12°C
Fresh air pretreatment to Summer DB12°C/WB12°C Winter DB25℃ Hot water inlet and outlet temperature 60°C/50℃
Steam temperature pressure 130°C/0.2M Pa
The parameter with “*” in the chart is a non-standard configuration of the device.
Electric reheating is divided into two forms, and the user can select one according to the size of the demand.
When ordering, users can choose cooling, heat, electric reheating, humidification, and filter rating according to different areas.
Performance / Model YJ13-5 YJ13.5-S YJ14-S YJ15-S YJ16-S YJ17-S YJ18.5-S YJ20-S YJ22-S YJ25-S
Rated volume m3/h 13000 13S00 14000 15000 16000 17000 18500 20000 22000 25000
External pressure Pa 650 660 650 650 650 650 650 650 650 650
Motor power Kw 7.5 7.5 11 11 11 11 11 11 11 15
Off-machine noise dB(A) ≤74 ≤74 ≤74 ≤74 ≤78 ≤78 ≤78 ≤78 ≤80 ≤80
Cooling Capacity
Kw
2-row tube 30.6 31.73 33.18 35.55 38.5 40.8 44.46 48.1 55.43 60.5
3-row tube 48.62 50.49 52.5 56.4 60.26 64.l 69.74 76 83.38 95
4-row tube 61.23 63.58 66.08 70.95 75.68 80.56 88.16 95.4 105.4 120.3
Water resistance  Kpa ≤ 60
Heating Capacity
KW
2 rows of hot water coil * 59.6 62.l 64.6 69.2 73.7 79.5 85.8 92.2 101.6 116.5
1 rows of steam coils * 78.4 81.9 85.7 91.6 97.4 103.9 112.8 124.6 134.5 152.3
Water resistance  Kpa ≤ 55
Electric heating Form(I)Kw 13 13 14 15 16 17 18.5 20 22 25
Form ( II ) Kw 19 19 21 22 24 26 28 30 33 38
Humidification Power KW < 17.25 < 17.25 < 17.25 < 17.25 < 17.25 < 17.25 < 26.25 < 26.25 < 26.25 < 26.25
Humidification amount Kg/h ≤23 ≤23 ≤23 ≤23 ≤23 ≤23 ≤35 ≤35 ≤35 ≤35
Coarse effect Type Plate type (multiple pleats) / chemical fiber non-woven filter material
Filter Filtration efficiency G4   particle size ≥ 5μm     Filtration efficiency≥75%
Initial/final resistance
Pa
≤50 / 100
Medium effect filter Type Bag type (Chemical fiber)
Filtration efficiency F8    Particle size ≥ 1μm Filtration efficiency ≥ 80%
Initial/final resistance
Pa
≤100 / 200
Note: Return air Summer D824℃/WB17.5C Winter DB23°C/WB15.5C Chilled water inlet and outlet temperature 7°C/12°C
Fresh air pretreatment to Summer DB12°C/WB12°C Winter DB25℃ Hot water inlet and outlet temperature 60°C/50℃
Steam temperature pressure 130°C/0.2M Pa
The parameter with “*” in the table is a non-standard configuration of the device.
Electric reheating is divided into two forms, and the user can select one according to the size of the demand.
When ordering, users can choose cooling, heat, electric reheating, humidification, and filter rating according to different areas.

Medical air conditioning purification air conditioning unit parameters

(Cold water type + new, return air mixing treatment)

Performance / Model YJ02-S YJ02.5-S YJ03-S YJ03.5-S YJ04-S YJ04.5-S YJ05-S YJ05.5-S YJ06-S YJ06.5-S YJ07-S
Rated volume m3/h 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000
External pressure Pa 650 650 650 650 650 650 650 650 650 650 650
Motor power Kw 1.5 2.2 2.2 2.2 3 3 3 3 4 4 4
Off-machine noise dB(A) ≤68 ≤70 ≤70 ≤70 ≤70 ≤70 ≤70 ≤70 ≤70 ≤72 ≤72
Cooling Capacity
Kw
4-row tube 10.6 13.25 16.1 18.7 21.4 24.21 27 29.81 32.3 34.9 37.8
6-row tube 14.65 18.3 22.1 25.7 29.4 33.l 36.8 40.5 44.2 47.9 51.6
8-row tube 16.7 20.9 25.1 29.3 33.5 37.7 41.9 46 50.3 54.4 58.7
Water resistance  Kpa ≤55 Kpa
Heating Capacity
KW
2 rows of hot water coil * 13.5 16.2 19.2 22 24 26.5 28.5 32 34.8 37.8 40
1 rows of steam coils * 15 17.5 20.3 23.7 25.4 28.5 30.4 33.1 36.5 40.1 42.6
Water resistance  Kpa ≤55 Kpa
Electric heating Form(I)Kw 2.5 3 4 4 5.5 5.5 6.5 6.5 7.8 7.8 8.8
Form ( II ) Kw 4 5 5 5 8 8 10 10 11 11 13.2
Electrode humidification Power KW <6.0 <6.0 <6.0 <6.0 <6.0 <6.0 <7.5 <7.5 <7.5 <7.5 <9.8
Humidification amount Kg/h ≤8.0 ≤8.0 ≤8.0 ≤8.0 ≤8.0 ≤8.0 ≤10 ≤10 ≤10 ≤10 ≤13
Fresh air warming up Kw* 5 5 5 5 7.5 7.5 7.5 7.5 7.5 7.5 10
Fresh air filtration Type Plate type (multiple pleats)
Filtration efficiency G2 Weighting method: ≥ 65%
Coarse effect Type Plate type (multiple pleats) / chemical fiber non-woven filter material
Filter Filtration efficiency G4   particle size ≥ 5μm     Filtration efficiency ≥ 75%
Initial/final resistance
Pa
≤ 50 / 100
Medium effect filter Type Bag type ( Chemical fiber )
Filtration efficiency F8     Particle size≥1μm     Filtration efficiency ≥ 80%
Initial/final resistance
Pa
≤100 / 200
Note: Return air Summer D824℃/WB17.5C Winter DB23°C/WB15.5C Chilled water inlet and outlet temperature 7°C/12°C
Fresh air pretreatment to Summer DB12°C/WB12°C Winter DB25℃ Hot water inlet and outlet temperature 60°C/50℃
Steam temperature pressure 130°C/0.2M Pa
The parameter with “*” in the table is a non-standard configuration of the device.
Electric reheating is divided into two forms, and the user can select one according to the size of the demand.
When ordering, users can choose cooling, heat, electric reheating, humidification, and filter rating according to different areas.
Performance/Model YJ07.5-S YJ08-S YJ08.5-S YJ09-S YJ09.5-S YJ10-S YJ10.5-S YJ11-S YJ11.5-S YJ12-S YJ12.5-S
Rated volume m3/h 7500 8000 8500 9000 9500 10000 10500 11000 11500 12000 12500
External pressure Pa 650 650 650 650 650 650 650 650 650 650 650
Motor power Kw 4 5.5 5.5 5.5 5.5 5.5 7.5 7.5 7.5 7.5 7.5
Off-machine noise dB(A) ≤72 ≤ 72 ≤ 72 ≤ 72 ≤72 ≤72 ≤74 ≤74 ≤ 74 ≤74 ≤ 74
Cooling Capacity
Kw
4-row tube 40.5 43.6 46.34 49.3 52.1 54.9 57.7 60.4 63.3 66.1 68.9
6-row tube 55.3 58.8 62.8 66.6 70.4 74.2 78.l 81.8 85.S 89.3 93.2
8-row tube 62.9 67.1 71.4 75.7 80 84.4 88.8 93.6 97.4 101.7 106.2
Water resistance  Kpa ≤ 55 Kpa
Heating Capacity
KW
2 rows of hot water coil * 42.7 44.9 47.6 49.5 52.3 55 56.7 58.3 60.8 62.9 65.1
1 rows of steam coils * 45 48.9 52 54.6 57.5 59.8 63.7 66 69.2 72.6 75.8
Water resistance  Kpa ≤ 55 Kpa
Electric heating Form(I)Kw 8.8 10.2 10.2 11.5 11.5 12.5 12.5 14 14 15 15
Form ( II ) Kw 13.2 16 16 17 17 19 19 21 21 22.5 22.5
Electrode humidification Power KW < 9.8 < 9.8 < 11.25 < 11.25 < 11.25 < .11.25 < 11.25 < 17.25 < 17.25 < 17.25 < 17.25
Humidification amount Kg/h ≤ 13 ≤13 ≤ 15 ≤15 ≤ 15 ≤ 15 ≤ 15 ≤23 ≤23 ≤ 23 ≤ 23
Fresh air warming up Kw* 10 10 10 10 10 15 15 15 15 15 15
Fresh air filtration Type Plate type (multiple pleats)
Filtration efficiency G2 Weighting method:  ≥ 65%
Coarse effect Type Plate type (multiple pleats) / chemical fiber non-woven filter material
Filter Filtration efficiency G4   particle size ≥ 5μm     Filtration efficiency ≥ 75%
Initial/final resistance
Pa
≤ 50 / 100
Medium effect filter Type Bag type (Chemical fiber)
Filtration efficiency F8 Particle size ≥ 1μm     Filtration efficiency ≥ 80%
Initial/final resistance
Pa
≤ 100 / 200
Note: Return air Summer D824℃/WB17.5C Winter DB23°C/WB15.5C Chilled water inlet and outlet temperature 7°C/12°C
Fresh air pretreatment to Summer DB12°C/WB12°C Winter DB25℃ Hot water inlet and outlet temperature 60°C/50℃
Steam temperature pressure 130°C/0.2M Pa
The parameter with “*” in the table is a non-standard configuration of the device.
Electric reheating is divided into two forms, and the user can select one according to the size of the demand.
When ordering, users can choose cooling, heat, electric reheating, humidification, and filter rating according to different areas.
Performance/Model YJ13-5 YJ13.5-S YJ14-S YJ15-S YJ16-S YJ17-S YJ18.5-S YJ20-S YJ22-S YJ25-S
Rated volume m3/h 13000 13S00 14000 15000 16000 17000 18500 20000 22000 25000
External pressure Pa 650 660 650 650 650 650 650 650 650 650
Motor power Kw 7.5 7.5 11 11 11 11 11 11 11 15
Off-machine noise dB(A) ≤74 ≤74 ≤74 ≤74 ≤78 ≤78 ≤78 ≤78 ≤80 ≤80
Cooling Capacity
Kw
4-row tube 71.6 74.5 77.8 83.4 89.2 95.1 103.6 112.5 122.8 139.9
6-row tube 96.85 100.7 104.6 112.6 120 127.7 139.2 150.6 165.7 188.5
8-row tube 110.5 114.9 119.3 128.1 136.7 145.4 158.4 171.4 188.6 214.5
Water resistance  Kpa ≤ 60 Kpa
Heating Capacity
KW
2 rows of hot water coil * 67.7 70.2 72.8 78 83.2 88.4 96.2 108 114.4 130
1 rows of steam coils * 78.4 81.9 85.7 91.6 97.4 103.9 112.8 124.6 134.5 152.3
Water resistance  Kpa ≤ 55 Kpa
Electric heating Form(I)Kw 16.8 16.8 18 19.2 20.5 21.5 23.5 25.6 28.2 32
Form ( II ) Kw 25.2 25.2 27 28.5 30.5 32.5 35.6 38.4 42.2 48
Humidification Power KW < 17.25 < 17.25 < 17.25 < 17.25 < 17.25 < 17.25 < 26.25 < 26.25 < 26.25 < 26.25
Humidification amount Kg/h ≤23 ≤23 ≤23 ≤23 ≤23 ≤23 ≤35 ≤35 ≤35 ≤35
Fresh air warming up Kw* 15 15 20 20 20 20 20 20 20 20
Coarse effect Type Plate type (multiple pleats) / chemical fiber non-woven filter material
Filter Filtration efficiency G4 particle size ≥ 5μm     Filtration efficiency ≥ 75%
Initial/final resistance
Pa
≤50 / 100
Medium effect filter Type Bag type (Chemical fiber)
Filtration efficiency F8 Particle size≥1μm Filtration efficiency ≥ 80%
Initial/final resistance
Pa
≤ 100 / 200
Note: Return air Summer D824℃/WB17.5C Winter DB23°C/WB15.5C Chilled water inlet and outlet temperature 7°C/12°C
Fresh air pretreatment to Summer DB12°C/WB12°C Winter DB25℃ Hot water inlet and outlet temperature 60°C/50℃
Steam temperature pressure 130°C/0.2M Pa
The parameter with “*” in the table is a non-standard configuration of the device.
Electric reheating is divided into two forms, and the user can select one according to the size of the demand.
When ordering, users can choose cooling, heat, electric reheating, humidification, and filter rating according to different areas.

Medical air conditioning purification air conditioning unit parameters

(cold water circulation type / fresh air independent treatment)

Model Unit size Tube size(DN) Tuyere size WGT
W H H1 L L1 L2 L3 D1 D2 D3 0.A(wxh) R.A(wxh) S.A(wxh) KG
YJ02-S 760 720 80 3840 980 1400 1600 25 20 25 320×212 320×316 400×320 369
YJ02.5-S 860 720 80 3840 980 1400 1600 25 20 25 320×212 320×316 400×320 388
YJ03-S 1000 720 80 3880 1020 1400 1600 25 20 25 320×212 400×316 500×320 426
YJ03.5-S 1050 780 80 3880 1020 1400 1600 32 25 25 320×212 500×316 630×320 458
YJ04-S 1200 780 80 3880 1020 1400 1600 32 25 25 320×212 500×316 630×320 486
YJ04.5-S 1200 830 80 4022 1162 1400 1600 32 25 25 400×212 S00x416 630×400 513
YJ05-S 1300 830 80 4022 1162 1400 1600 32 32 25 400×212 500×416 630×400 556
YJ05.5-S 1340 880 80 4022 1162 1400 1600 40 32 25 400×312 600×416 630×400 597
YJ06-S 1340 930 80 4022 1162 1400 1600 40 32 25 400×312 600×416 630×500 643
YJ06.5-S 1340 950 80 4213 1253 1400 1700 40 32 25 500×312 650×416 630×500 695
YJ07-S 1340 980 80 4213 1253 1400 1700 40 32 25 500×312 650×520 700×500 718
YJ07.5-S 1340 1040 80 4213 1253 1400 1700 40 32 25 500×312 650×520 700×500 749
YJ08-S 1420 1040 100 4300 1340 1400 1700 40 40 25 500×312 700×520 800×500 796
YJ08.5-S 1420 1100 100 4300 1340 1400 1700 40 40 25 500×312 700Jx520 800×500 821
YJ09-S 1420 1165 100 4350 1390 1500 1700 50 40 25 500×312 800×520 800×500 847
YJ09.5 S 1420 1225 100 4350 1390 1500 1700 50 40 25 500×416 800×520 800×600 873

Get Quote

Contact Us

Quote Now