>>>Vertical Exposed Fan Coil Unit

Vertical Exposed Fan Coil Unit

  • Vertical surface fan coil is mounted on the wall side of the room.
  • The air volume is from 340 to 2380 m3/h. The cooling capacity is from 1.8 to 12.6 kW.
  • No high static pressure type and four tube type fan coil unit. 
  • It can be used directly for large temperature difference conditions.
  • Also can provide dry fan coil unit.
Categories: ,

Description

The vertical surface fan coil is mounted on the wall side of the room. The air volume is from 340 to 2380 m3/h. The cooling capacity is from 1.8 to 12.6 kW. No high static pressure type and four tube type fan coil unit. It can be used directly for large temperature difference conditions. Also can provide dry fan coil unit.

Feature or Static Pressure: C4-four tube type, T7-large temperature difference, G30: 30Pa/G50: 50 Pa.

Installation type: A-concealed, M-surface.

Structure: W-Horizontal, L-Vertical, TK-ceilling

Nominal air volume: Number × 10m3 / h

FP- standard fan coil: FPG stands for dry fan coil

National Standard Technical Specifications of FP Series Fan Coil Unit

Index Project FP-34 FP-51 FP-68 FP-85 FP-102 FP-136 FP-170 FP-204 FP-238
Rated air flow H m3/h 340 510 680 850 1020 1360 1700 2040 2380
M m3/h 250 380 510 630 760 1020 1270 1530 1780
L m3/h 170 250 340 420 510 680 850 1020 1190
Rated cooling capacity H W 1800 2700 3600 4500 5400 7200 9000 10800 12600
M W 1590 2300 3160 3900 4600 6330 7750 9200 10800
L W 1260 1800 2520 3100 3700 5040 6200 7300 8700
Heat H W 2700 4050 5400 6750 8100 10800 13500 16200 18900
Input power LSP W 37 52 62 76 96 134 152 189 228
30Pa W 44 59 72 87 108 156 174 212 253
Unit noise LSP dB(A) 37 39 41 43 45 46 48 50 52
30Pa dB(A) 40 42 44 46 47 48 50 52 54
Coil Model Φ9.52 Copper Tube through Aluminum fins / 3 rows of 8 holes / Standard sheet distance
WF kg/h 310 465 620 775 930 1240 1550 1850 2160
WR kPa 30 33 33 33 44 44 44 44 55
Fan Model Φ160 double inlet centrifugal fan
QTY SET 1 1 2 2 2 3 4 4 4
Motor Model Single-phase capacitor running three-speed motor
QTY SET 1 1 1 1 1 2 2 2 2
Interface Water pipe Interface Water in/ out pipe: 3/4" inside thread /Condensing water pipe: 3/4" outside thread
Electrical Interface Terminals ( five core wire high / medium / low / zero / ground )
WGT/kg Standard 12 13 17 18 19 26 29 33 36
With return air box 14 15 20 21 23 31 34 38 42
LA 20 21 25 27 29 38 46 50 52
LM 21 22 23 26 27 31 34 40 43
WM 21 22 23 26 27 31 34 40 43
TK 21 22 22 26 27 28 33 33 34

Remark: LSP(low static pressure); WF(Water flow); WR(water resistance)

Technical Description:

1. Date under cooling condition: Air inlet DB/WB: 27/19.5℃; water inlet temperature 7℃; the temperature difference 5 ℃.

2. The cooling capacity of the unit: surface air cooler: 2.12mm standard slice distance; Adjust the slice distance to change the heat transfer area, the cooling capacity can be changed.

3. Date under heating condition: Air inlet DB/WB: DB21℃; water inlet temperature 60℃. The same water condition as refrigeration.

4. Unit noise: One meter measurement in front of and below the unit. The high static pressure unit needs to be installed with a return air duct. It is controlled at the air outlet after controlling the static pressure.

5. The above date complies with 12Pa low static pressure of external unit and 30Pa high static pressure . If the users need 50Pa high static, pls specify.