- The vertical concealed fan coil is hidden in the wall channel or walkway. The air volume range is 340~2380m3/h. The cooling capacity is from 1.8~12.6kW. The common high static pressure is 30Pa and the special high static pressure is up to 50Pa. Without four tube type fan coil unit, can be used directly for large temperature difference conditions. Also can provide dry fan coil unit.
Vertical Concealed Fan Coil Unit
Description
Feature or Static Pressure: C4-four tube type, T7-large temperature difference, G30: 30Pa/G50: 50 Pa.
Installation type: A-concealed, M-surface.
Structure: W-Horizontal, L-Vertical, TK-ceilling
Nominal air volume: Number × 10m3 / h
FP- standard fan coil: FPG stands for dry fan coil
Index | Project | -34WAC4 | -51WAC4 | -68WAC4 | -85WAC4 | -102WAC4 | -136WAC4 | -170WAC4 | -204WAC4 | -238WAC4 | ||
Rated air flow | H | m3/h | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 | |
M | m3/h | 250 | 380 | 510 | 630 | 760 | 1020 | 1270 | 1530 | 1780 | ||
L | m3/h | 170 | 250 | 340 | 420 | 510 | 680 | 850 | 1020 | 1190 | ||
Rated cooling capacity | H | W | 1800 | 2700 | 3600 | 4500 | 5400 | 7200 | 9000 | 10800 | 12600 | |
M | W | 1590 | 2300 | 3160 | 3900 | 4600 | 6330 | 7750 | 9200 | 10800 | ||
L | W | 1260 | 1800 | 2520 | 3100 | 3700 | 5040 | 6200 | 7300 | 8700 | ||
Hot coil heat | H | W | 1450 | 2160 | 2880 | 3600 | 4320 | 5400 | 6600 | 7600 | 8800 | |
M | W | 1260 | 1880 | 2500 | 3130 | 3750 | 4700 | 5740 | 6610 | 7650 | ||
L | W | 1010 | 1510 | 2010 | 2520 | 3020 | 3780 | 4620 | 5320 | 6160 | ||
Input power |
LSP | W | 37 | 52 | 62 | 76 | 96 | 134 | 152 | 189 | 228 | |
30Pa | W | 44 | 59 | 72 | 87 | 108 | 156 | 174 | 212 | 253 | ||
Unit noise | LSP | dB(A) | 37 | 39 | 41 | 43 | 45 | 46 | 48 | 50 | 52 | |
30Pa | dB(A) | 40 | 42 | 44 | 46 | 47 | 48 | 50 | 52 | 54 | ||
Cold water coil | Model | Φ9.52 Copper Tube through Aluminum fins / 3 rows of 8 holes / Standard Sheet Distance | ||||||||||
WF | kg/h | 310 | 465 | 620 | 775 | 930 | 1240 | 1550 | 1850 | 2160 | ||
WR | kPa | 30 | 33 | 33 | 33 | 44 | 44 | 44 | 44 | 55 | ||
Hot water coil | Model | Φ9.52 Copper Tube through Aluminum fins / 3 rows of 8 holes / Standard Sheet distance | ||||||||||
WF | kg/h | 250 | 370 | 495 | 620 | 743 | 930 | 1140 | 1300 | 1510 | ||
WR | kPa | 30 | 40 | 50 | 60 | 70 | 75 | 80 | 85 | 90 | ||
Fan | Model | Φ160 double inlet centrifugal fan | ||||||||||
QTY | SET | 1 | 1 | 2 | 2 | 2 | 3 | 4 | 4 | 4 | ||
Motor | Model | Single-phase capacitor running three-speed motor | ||||||||||
QTY | SET | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | ||
Interface | Water pipe Interface | Water in/ out pipe: 3/4" inside thread/Condensing water pipe: 3/4" outside thread | ||||||||||
Electrical Interface | Terminals ( five core wire high / medium / low / zero / ground ) | |||||||||||
WGT/kg | Standard | 13 | 14 | 18 | 20 | 21 | 28 | 31 | 35 | 38 | ||
With return air box | 15 | 16 | 21 | 23 | 25 | 33 | 36 | 40 | 44 | |||
Remark: LSP(low static pressure); WF(Water flow); WR(water resistance) ◆ Technical Description: 1. Date under cooling condition: Air inlet DB/WB: 27/19.5℃; water inlet temperature 7℃; the temperature difference 5 ℃. 2. The cooling capacity of the unit: surface air cooler: 2.12mm standard slice distance; Adjust the slice distance to change the heat transfer area, the cooling capacity can be changed. 3. Date under heating condition: Air inlet DB/WB: DB21℃; water inlet temperature 60℃; the temperature difference 5 ℃. The same water condition as refrigeration. 4. Unit noise: One meter measurement in front of and below the unit. 5. The above date complies with 12Pa low static pressure of external unit and 30Pa high static pressure . If the users need 50Pa high static, pls specify. |
Installation Dimension Chart of Vertical Concealed Fan Coil Unit
FP- | 34LA | 51LA | 68LA | 85LA | 102LA | 136LA | 170LA | 204LA | 238LA |
A | 695 | 760 | 960 | 1060 | 1180 | 1470 | 1590 | 1790 | 1990 |
B | 595 | 660 | 860 | 960 | 1080 | 1370 | 1490 | 1690 | 1890 |
C | 545 | 610 | 810 | 910 | 1010 | 1320 | 1440 | 1640 | 1840 |