- Machinery Industry: Control the oil temperature of hydraulic system. Guarantee the precision of hydraulic.
- Pressure and equipment’s normal, safe and effective work. Prolong oil’s service life.
- Electroplating Industry: Control the temperature of electroplating liquid and improve the quality of. electroplating products.
- Plastic Industry: Control mould’s temperature and improve products’ quality.
- Vacuum Industry: Accurately control boiler’s temperature and ensure product’s quality in order to improve. productivity.
- Electronics Industry: Stabilize electronic components’ internal molecular structure during production for protecting it.
- Food Industry: Stabilize storage temperature for great food quality.
Air Conditioning Unit–Air Cooled Series
Description
◆ Machinery Industry: Control the oil temperature of hydraulic system. Guarantee the precision of hydraulic.
pressure and equipment’s normal, safe and effective work. Prolong oil’s service life.
◆ Electroplating Industry: Control the temperature of electroplating liquid and improve the quality of. electroplating products.
◆ Plastic Industry: Control mould’s temperature and improve products’ quality.
◆ Vacuum Industry: Accurately control boiler’s temperature and ensure product’s quality in order to improve. productivity.
◆ Electronics Industry: Stabilize electronic components’ internal molecular structure during production for protecting it.
◆ Food Industry: Stabilize storage temperature for great food quality.
According to the requirements for different working condition or application location, Akawell has single-cooling unit, electric heating unit, heat pump unit, constant temperature and humidity unit for option. Akawell can meet all kinds of commercial and industrial application requirement by many types and wide-range cooling capacity unit.
AKA- | A- | 15- | GH- | V/H- | A- | A4 |
Akawell Single Unit | Air Cooling | Nominal Cooling Capacity (KW) | GH: Air-cooling
EH: Electric Heater HU: Precision Control HP: Heat Pump |
V: Vertical
H: Horizontal |
Air-out Mode | A4 -R410a |
◆ AKA-A-GH
Single Air-conditioning Unit—Air-cooling: It applies to indoor air-conditioning for commercial, residential and industrial building. It is very suitable for place where thermal load in summer is great and no need for heat in winter. It is also the first option for industrial or mining enterprise whose working environment has much thermal load all through year and it is necessary to reduce indoor temperature.
◆ AKA-A-EH
Single Air-conditioning Unit—Electrical-heating: For site where thermal load is great in summer and no need heating in winter.
◆ AKA-A-HU
Single Air-conditioning Unit—Air-cooling Constant Temperature & Humidity: For site where it is required to accurately control the temperature and humidity.
◆ AKA-A-HP
Single Air-conditioning Unit—Air-cooling Heat Pump Unit: For site where air conditioning is required all through year for commercial, residential and industrial application. Standard operating condition like: Cooling capacity from 10 KW to 335KW, heating capacity from 10.5KW to 345KW and humidification capacity from 4KG/H to 45KG/H.
Unit Type | Supply Air Way | Model | No. | Diagram(Side View) | |
Vertical Unit | Side Outflow | Front Inflow
Front Outflow |
AKA-A-10~80-V | A | / |
Top Outflow |
Front Inflow Top Outflow |
AKA-A-10~80-V | B | / | |
Back Inflow Top Outflow |
AKA-A-80~350-V | C | / | ||
Horizontal Unit | Horizontal Outflow | Front Inflow
back Outflow |
AKA-A-10~80-V | D | / |
Unit Type | AKA-A-10-GH- | AKA-A-15-GH- | AKA-A-25-GH- | ||
Air Volume | M3/H | 2,000 | 3,000 | 4,000 | |
Refrigerating Capacity | KW | 10 | 14.6 | 25 | |
Heating Capacity(Electrical Heating) | KW | 5 | 8 | 10 | |
Heat Pump Heat(Air-cooling Heat Pump) | KW | 10.5 | 15.5 | 26.8 | |
Humidification Capacity (Constant Temperature & Humidity) |
KGS/H | 4 | 4 | 8 | |
Static Pressure | Pa | 80 | 100 | 120 | |
Unit’s Noise | dB(A) | 63 | 64 | 65 | |
Refrigerating Power | KW | 3.4 | 5.2 | 8.5 | |
Max Total Power (Constant Temperature & Humidity) |
KW | 9.5 | 15.9 | 23.5 | |
Power | 380V/3PH/50Hz | ||||
Air-out Way | Horizontal/Top | ||||
Blower |
Double-inlet Wind Centrifugal Blower (Direct Connection With Outer Rotor / Belt Gearing) |
||||
Temperature Range | 24℃~30℃±1℃ | ||||
Air Filter |
Primary Filter for Ordinary Cabinet Panel Primary Filter G4 for Constant Temperature & Humidity Unit |
||||
Indoor Unit Dimension (Horizontal) |
Length | MM | 1,150 | 1,150 | 1,150 |
Width | MM | 1,050 | 1,050 | 1,200 | |
Height | MM | 800 | 800 | 950 | |
Net Weight of Horizontal Unit(GH/HU) | KGS | 150/160 | 170/180 | 180/200 | |
Indoor Unit Dimension (Vertical) |
Length | MM | 1,150 | 1,150 | 1,250 |
Width | MM | 600 | 600 | 650 | |
Height | MM | 1,850 (Side Outlet 2,200) | 1,850 (Side Outlet 2,200) | 1,850 (Side Outlet 2,200) | |
Net Weight of Vertical Unit(GH/HU) | KGS | 160/170 | 180/200 | 200/220 | |
Compressor | Type | Double-rotor Compressor | |||
Max Operating Current | A | 8.6 | 10 | 8.6 x 2 | |
Refrigerating | Type | R22/R410a | |||
Filling Quantity | KGS | 2.5 | 4 | 6.5 | |
Outdoor Unit Dimension |
Length | MM | 880 | 930 | 810(1,250) |
Width | MM | 360 | 390 | 810(450) | |
Height | MM | 800 | 1,270 | 1,260(1,250) | |
Unit’s Net Weight | KGS | 85 | 120 | 190 / 220 | |
Copper Pipe Between Inner and Outer Unit | Liquid Supply Pipe Diameter × Quantity | — | Φ12.7 × 1 | Φ12.7 × 1 | Φ12.7 × 2 |
Return Air Pipe Diameter × Quantity | — | Φ15.8 × 1 | Φ19 × 1 | Φ15.8 × 2 |
AKA-A-35-GH | AKA-A-40-GH | AKA-A-50-GH | AKA-A-65-GH | AKA-A-80-GH |
6,000 | 7,000 | 9,000 | 11,000 | 13,000 |
32.2 | 40 | 46.8 | 63.5 | 73 |
15 | 20 | 25 | 30 | 40 |
33 | 42 | 50 | 65 | 80 |
8 | 8 | 15 | 15 | 15 |
150 | 180 | 200 | 250 | 300 |
66 | 67 | 69 | 70 | 71 |
10.5 | 12.6 | 15.7 | 21.3 | 24.5 |
31.1 | 38.2 | 49.1 | 62.2 | 74.5 |
380V/3PH/50Hz | ||||
Horizontal/Top | ||||
Double-inlet Wind Centrifugal Blower (Direct Connection With Outer Rotor/Belt Gearing) |
Double-inlet Wind Centrifugal Blower (Belt Gearing) | |||
24℃~30℃±1℃ | ||||
Primary Filter for Ordinary Cabinet Panel Primary Filter G4 for Constant Temperature & Humidity Unit |
||||
1,150 | 1,150 | 1,440 | 1,440 | 1,720 |
1,200 | 1,200 | 1,600 | 1,600 | 1,600 |
950 | 950 | 1,050 | 1,050 | 1,250 |
250/280 | 270/300 | 350/380 | 400/450 | 520/600 |
1,400 | 1,400 | 1,900 | 2,100 | 2,100 |
650 | 650 | 650 | 650 | 650 |
1,850(Side Out-let 2,200) | 1,850(Side Out-let 2,200) | 2,050(Side Out-let 2,400) | 2,050(Side Out-let 2,400) | 2,050(Side Out-let 2,400) |
280/300 | 310/330 | 400/450 | 420/470 | 600/700 |
Fully Enclosed Scroll Compressor | ||||
20 | 22 | 10 + 20 | 2 x 20 | 2 x 22 |
R22/R410a | ||||
8 | 9 | 4 + 8 | 2 x 8 | 2 x 9 |
1,450(1,700) | 1,450(1,700) | 1,650 | 1,700 | 1,800 |
725(550) | 725(550) | 900 | 1,100 | 1,060 |
1,060(1,635) | 1,060(1,635) | 1,386 | 1,700 | 1,950 |
220/240 | 220/240 | 350 | 400 | 450 |
Φ15.8 × 1 | Φ15.8 × 1 | Φ12.7 + Φ15.8 | Φ15.8 × 2 | Φ15.8 × 2 |
Φ28 × 1 | Φ28 × 1 | Φ19 + Φ28 | Φ28 × 2 | Φ28 × 2 |
AKA-A-100-GH | AKA-A-140-GH | AKA-A-170-GH | AKA-A-260-GH | AKA-A-350-GH |
16,000 | 22,000 | 30,000 | 45,000 | 60,000 |
96 | 138 | 165 | 252 | 335 |
45 | 65 | 65 | 100 | 120 |
102 | 142 | 175 | 265 | 345 |
15 | 23 | 23 | 32 | 45 |
350 | 400 | 450 | 500 | 600 |
72 | 74 | 76 | 78 | 80 |
33.9 | 46.5 | 58.5 | 83.5 | 113 |
89.9 | 132.2 | 138.5 | 204.5 | 263 |
380V/3PH/50Hz | ||||
Horizontal/Top | ||||
Double-inlet Wind Centrifugal Blower (Belt Gearing) | ||||
24℃~30℃±1℃ | ||||
Primary Filter for Ordinary Cabinet Panel Primary Filter G4 for Constant Temperature & Humidity Unit |
||||
/ | / | / | / | / |
/ | / | / | / | / |
/ | / | / | / | / |
/ | / | / | / | / |
2,100 | 2,100 | 3,000 | 3,200 | 3,200 |
1,200 | 1,400 | 1,600 | 1,800 | 1,800 |
2,050 | 2,050 | 2,400 | 2,400 | 2,400 |
750/880 | 850/980 | 950/1,100 | 1,250/1,500 | 1,450/1,650 |
Fully Enclosed Scroll Compressor | ||||
3 x 20 | 4 x 40 | 2 x 45 | 3 x 45 | 4 x 45 |
R22/R410a | ||||
3 x 8 | 4 x 8 | 2 x 19 | 3 x 19 | 4 x 19 |
2,300 | 2,000 | 2,000 | 2,200 | 2,200 |
1,100 | 1,720 | 1,720 | 2,100 | 2,100 |
1,950 | 1,950 | 1,950 | 2,400 | 2,400 |
620 | 850 | 1,000 | 1,250 | 1,700 |
Φ15.8 × 3 | Φ15.8 × 4 | Φ22 × 2 | Φ22 × 3 | Φ22 × 4 |
Φ28 × 3 | Φ28 × 4 | Φ38 × 2 | Φ38 × 3 | Φ38 × 4 |
Remarks: |
1. Unit’s standard operating condition: Indoor Side-in Wind Temperature: DB: 27℃ WB: 19℃ Outdoor Side-in Wind Temperature: DB: 35℃ WB: 24℃ |
|||
2. General configuration for outdoor unit is top outlet wind and side outlet wind for indoor unit. | ||||
3. Non-standard model could be customized. Welcome to check with Akawell any time. |