- The cassette type (semi-surface mounted) fan coil is embedded in the ceiling.
- The air volume range is 340~2380m3/h.
- The cooling capacity range is 1.8~12.6kW.
- No high static pressure type and four tube type fan coil unit.
- It can be used directly for large temperature difference conditions.
- Also can provide dry fan coil units.
Ceiling Cabinet Type Fan Coil Unit
Description
FP-TK series:
The cassette type (semi-surface mounted) fan coil is embedded in the ceiling. The air volume range is 340~2380m3/h. The cooling capacity range is 1.8~12.6kW. No high static pressure type and four tube type fan coil unit. It can be used directly for large temperature difference conditions. Also can provide dry fan coil units.
National Standard Technical Specifications of FP Series Fan Coil Unit
Index |
Project | FP-34 | FP-51 | FP-68 | FP-85 | FP-102 | FP-136 | FP-170 | FP-204 |
FP-238 |
|
Rated air flow |
H |
m3/h | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 |
2380 |
M |
m3/h | 250 | 380 | 510 | 630 | 760 | 1020 | 1270 | 1530 |
1780 |
|
L |
m3/h | 170 | 250 | 340 | 420 | 510 | 680 | 850 | 1020 | 1190 | |
Rated cooling capacity |
H |
W | 1800 | 2700 | 3600 | 4500 | 5400 | 7200 | 9000 | 10800 |
12600 |
M |
W | 1590 | 2300 | 3160 | 3900 | 4600 | 6330 | 7750 | 9200 |
10800 |
|
L |
W | 1260 | 1800 | 2520 | 3100 | 3700 | 5040 | 6200 | 7300 |
8700 |
|
Heat |
H |
W | 2700 | 4050 | 5400 | 6750 | 8100 | 10800 | 13500 | 16200 |
18900 |
Input power |
LSP | W | 37 | 52 | 62 | 76 | 96 | 134 | 152 | 189 |
228 |
30Pa |
W | 44 | 59 | 72 | 87 | 108 | 156 | 174 | 212 |
253 |
|
Unit noise |
LSP | dB(A) | 37 | 39 | 41 | 43 | 45 | 46 | 48 | 50 |
52 |
30Pa |
dB(A) | 40 | 42 | 44 | 46 | 47 | 48 | 50 | 52 |
54 |
|
Coil |
Model |
Φ9.52 Copper Tube through Aluminum fins / 3 rows of 8 holes / Standard sheet distance |
|||||||||
WF |
kg/h | 310 | 465 | 620 | 775 | 930 | 1240 | 1550 | 1850 |
2160 |
|
WR |
kPa | 30 | 33 | 33 | 33 | 44 | 44 | 44 | 44 |
55 |
|
Fan |
Model |
Φ160 double inlet centrifugal fan |
|||||||||
QTY |
SET |
1 | 1 | 2 | 2 | 2 | 3 | 4 | 4 |
4 |
|
Motor |
Model |
Single-phase capacitor running three-speed motor |
|||||||||
QTY |
SET | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 |
2 |
|
Interface |
Water pipe Interface |
Water in/ out pipe: 3/4" inside thread /Condensing water pipe: 3/4" outside thread |
|||||||||
Electrical Interface |
Terminals ( five core wire high / medium / low / zero / ground ) |
||||||||||
WGT/kg |
Standard | 12 | 13 | 17 | 18 | 19 | 26 | 29 | 33 |
36 |
|
With return air box |
14 | 15 | 20 | 21 | 23 | 31 | 34 | 38 |
42 |
||
LA |
20 | 21 | 25 | 27 | 29 | 38 | 46 | 50 | 52 | ||
LM |
21 | 22 | 23 | 26 | 27 | 31 | 34 | 40 |
43 |
||
WM |
21 | 22 | 23 | 26 | 27 | 31 | 34 | 40 |
43 |
||
TK |
21 | 22 | 22 | 26 | 27 | 28 | 33 | 33 |
34 |
||
Remark: LSP(low static pressure); WF(Water flow); WR(water resistance) ◆ Technical Description: 1. Date under cooling condition: Air inlet DB/WB: 27/19.5℃; water inlet temperature 7℃; the temperature difference 5 ℃. 2. The cooling capacity of the unit: surface air cooler: 2.12mm standard slice distance; Adjust the slice distance to change the heat transfer area, the cooling capacity can be changed. 3. Date under heating condition: Air inlet DB/WB: DB21℃; water inlet temperature 60℃. The same water condition as refrigeration. 4. Unit noise: One meter measurement in front of and below the unit. The high static pressure unit needs to be installed with a return air duct. It is controlled at the air outlet after controlling the static pressure. 5. The above date complies with 12Pa low static pressure of external unit and 30Pa high static pressure . If the users need 50Pa high static, pls specify. |
FP-T7 Series Large Temperature Difference for Cooling Fan Coil Unit Technical Specifications
Index | Project | FP-34 | FP-51 | FP-68 | FP-85 | FP-102 | FP-136 | FP-170 | FP-204 |
FP-238 |
|
Rated air flow |
H |
m3/h | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 |
2380 |
M |
m3/h | 250 | 380 | 510 | 630 | 760 | 1020 | 1270 | 1530 |
1780 |
|
L |
m3/h | 170 | 250 | 340 | 420 | 510 | 680 | 850 | 1020 |
1190 |
|
Rated cooling capacity |
H |
W | 1750 | 2620 | 3600 | 4500 | 5400 | 7200 | 9000 | 10800 |
12210 |
M |
W | 1550 | 2230 | 3160 | 3900 | 4600 | 6330 | 7750 | 9200 |
10470 |
|
L |
W | 1230 | 1750 | 2520 | 3100 | 3700 | 5040 | 6200 | 7300 |
8440 |
|
Heat |
H |
W | 2620 | 3930 | 5400 | 6750 | 8100 | 10800 | 13500 | 16200 |
18320 |
Input power |
LSP |
W | 37 | 52 | 62 | 76 | 96 | 134 | 152 | 189 |
228 |
30Pa |
W | 44 | 59 | 72 | 87 | 108 | 156 | 174 | 212 |
253 |
|
Unit noise |
LSP | dB(A) | 37 | 39 | 41 | 43 | 45 | 46 | 48 | 50 |
52 |
30Pa |
dB(A) | 40 | 42 | 44 | 46 | 47 | 48 | 50 | 52 |
54 |
|
Coil |
Model |
Φ9.52 Copper Tube through Aluminum fins / 3 rows of 8 holes / Standard Sheet Distance |
|||||||||
WF |
kg/h | 215 | 325 | 445 | 555 | 665 | 885 | 1110 | 1330 |
1505 |
|
WR |
kPa | 15 | 17 | 35 | 38 | 48 | 40 | 42 | 49 |
35 |
|
Fan |
Model |
Φ160 double inlet centrifugal fan |
|||||||||
QTY |
SET | 1 | 1 | 2 | 2 | 2 | 3 | 4 | 4 |
4 |
|
Motor |
Model |
Single-phase capacitor running three-speed motor |
|||||||||
QTY |
SET | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 |
2 |
|
Interface |
Water pipe Interface |
Water in/ out pipe: 3/4" inside thread/Condensing water pipe: 3/4" outside thread |
|||||||||
Electrical Interface |
Terminals ( five core wire high / medium / low / zero / ground ) | ||||||||||
WGT/kg |
Standard |
12 | 13 | 17 | 18 | 19 | 26 | 29 | 33 | 36 | |
With return air box |
14 | 15 | 20 | 21 | 23 | 31 | 34 | 38 | 42 | ||
LA |
20 |
21 | 25 | 27 | 29 | 38 | 46 | 50 |
52 |
||
LM |
21 | 22 | 23 | 26 | 27 | 31 | 34 | 40 |
43 |
||
WM |
21 | 22 | 23 | 26 | 27 | 31 | 34 | 40 |
43 |
||
TK |
21 | 22 | 22 | 26 | 27 | 28 | 33 | 33 |
34 |
||
Remark: LSP(low static pressure); WF(Water flow); WR(water resistance) ◆ Technical Description: 1. Date under cooling condition: Air inlet DB/WB: 27/19.5℃; water inlet temperature 6℃; the temperature difference 7 ℃. 2. The cooling capacity of the unit: surface air cooler: 2.12mm standard slice distance; Adjust the slice distance to change the heat transfer area, the cooling capacity can be changed. 3. Date under heating condition: Air inlet DB/WB: DB21℃; water inlet temperature 60℃. The same water condition as refrigeration. 4. Unit noise: One meter measurement in front of and below the unit. The high static pressure unit needs to be installed with a return air duct. It is controlled at the air outlet after controlling the static pressure. 5. The above date complies with 12Pa low static pressure of external unit and 30Pa high static pressure . If the users need 50Pa high static, pls specify. |
Installation Dimension Chart of Cassette&Ceiling Fan Coil Unit
Spec. Model |
Code | FP-34TK,FP-51TK,
FP-68KT |
FP-85TK,FP-102TK
FP-136TK |
FP-170TK,FP-204TK , FP-238TK |
Display Size |
A*B | 680×680 | 830×830 |
980×980 |
Machine Size |
L*S | 580×580 | 710×710 |
832×832 |
Lifting size |
H*K | 614×424 | 739×338 |
864×416 |
Remark: This picture shows the height of the free drainage unit. The height of the forced drainage unit is 320mm. |